Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Biomedical and Environmental Sciences ; (12): 709-717, 2015.
Article in English | WPRIM | ID: wpr-258885

ABSTRACT

<p><b>OBJECTIVE</b>Chinese allergic subjects have high levels of sensitization to house dust mite (HDM) and other indoor allergens. This study quantifies common indoor allergen levels in Chinese households.</p><p><b>METHODS</b>Dust samples were collected from nine cities. Major allergens Der p 1 and Der f 1 from Dermatophagoides pteronyssinus and D. farinae, and specific antigens of Blomia tropicalis, Tyrophagus putrescentiae, Acarus siro, and cockroach species Blattella germanica and Periplaneta americana were measured by ELISA.</p><p><b>RESULTS</b>HDM allergens were found in dust samples from bedding in 95% of the Chinese households. The median levels varied from <0.006 to 9.2 µg/g of dust, depending on the city. The percentages of households having HDM allergen levels associated with the risk of developing allergy sensitization and asthma were 65% and 25%, respectively. Specific antigens of the storage mite and cockroach were only found in samples from the southern and tropical regions of China. Levels of mite allergens were generally higher in samples from bedding compared to samples from the living room, even for storage mites, whereas levels of cockroach antigens were higher in the living room samples.</p><p><b>CONCLUSION</b>HDM allergens are present in bedding dust samples from most Chinese households. Cities in southern and central China have relatively high levels of HDM major allergens compared to cities in northern and western China. Antigens of storage mites and cockroaches are not as common as HDM allergens.</p>


Subject(s)
Animals , Air Pollution, Indoor , Allergens , Chemistry , Bedding and Linens , China , Cockroaches , Dust , Housing , Pyroglyphidae , Seasons
2.
Journal of Korean Medical Science ; : 166-173, 2011.
Article in English | WPRIM | ID: wpr-209765

ABSTRACT

There are few studies about school-environment in relation to pupils' respiratory health, and Korean school-environment has not been characterized. All pupils in 4th grade in 12 selected schools in three urban cities in Korea received a questionnaire (n = 2,453), 96% participated. Gaseous pollutants and ultrafine particles (UFPs) were measured indoors (n = 34) and outdoors (n = 12) during winter, 2004. Indoor dampness at home was investigated by the questionnaire. To evaluate associations between respiratory health and environment, multiple logistic- and multi-level regression models were applied adjusting for potential confounders. The mean age of pupils was 10 yr and 49% were boys. No school had mechanical ventilation and CO2-levels exceeded 1,000 ppm in all except one of the classrooms. The indoor mean concentrations of SO2, NO2, O3 and formaldehyde were 0.6 microg/m3, 19 microg/m3, 8 microg/m3 and 28 microg/m3, respectively. The average level of UFPs was 18,230 pt/cm3 in the classrooms and 16,480 pt/cm3 outdoors. There were positive associations between wheeze and outdoor NO2, and between current asthma and outdoor UFPs. With dampness at home, pupils had more wheeze. In conclusion, outdoor UFPs and even low levels of NO2 may adversely contribute to respiratory health in children. High CO2-levels in classrooms and indoor dampness/mold at home should be reduced.


Subject(s)
Child , Humans , Male , Air Pollutants , Air Pollution , Asthma , Carbon Dioxide , Cross-Sectional Studies , Environment , Humidity , Nitrates , Surveys and Questionnaires , Republic of Korea , Respiratory Sounds , Schools , Sulfur Dioxide
SELECTION OF CITATIONS
SEARCH DETAIL